Multi-drive System

Your Professional Multi-drive System Supplier!

 

RENLE was founded in 1999 and has remained dedicated to the R&D, production,and sales ofelectrical equipment, committed to providing global customers with efficient,energy-saving, and stable industrial control solution.

 
 

Why Choose Us

 

 

Professional Team

The company insists on people-oriented and technological innovation, and the R&D team accounts for more than 30% of the total number of employees. Invested heavily in the introduction of a complete set of precision instruments and experimental equipment.

 

Sales Market

Our product Export United States, Vietnam, Japan, Britain, Italy, Russia, India, Brazil, Spain, the Middle East and other countries and regions.

 

Rich Experience

We has 20+ years of research, 120 Professional sales service, engineers / person and 35 Presence in /countries.

 
High Speed Rewinding Machine manufacturers

Multi-drive System - Overview

 

A multi-drive system is an integrated power control system that uses one rectifier and a common DC bus bar to supply power to multiple individual inverter modules, each controlling a separate motor. This setup simplifies cabling and reduces costs, improves energy efficiency through energy regeneration, and enables sophisticated control and coordination of multiple motors, which is particularly useful for applications like paper machines, rolling mills, and automated production lines.

Product Specification

 

We offers the Drives Used in Paper Mills specifications

Items

Specification

Input

Rated input voltage

4T: 515VDC ; 6T: 930VDC

Input voltage range

Fluctuation of voltage: -15% - +10%

Output

Output voltage range

4T: 0 - 380VAC 0 - 600Hz
6T: 0 - 690VAC 0 - 600Hz

Control Performance

Control mode

V/F Control, Speed sensorless vector control, Speed sensor vector control

Range of speed regulation

1:100 (peed sensorless vector control); 1:1000 (Speed sensor vector control)

Steady speed precision

+ 0.5% (Speed sensorless vector control); + 0.2%(Speed sensor vector control)

Torque response

<20mS(Speed sensorless vector control); 5mS(Speed sensor vector control)

Torque control accuracy

+ 5% (Speed sensorless vector control): + 3% (Speed sensor vector control)

Basic function

Overload capacity

Inverter Unit:150% Rated current 60S;180o/ Rated current10S;200% Rated current 1S

Automatic voltage regulation

When the voltage of power gird changes, stable output voltage can be maintained automatically.

Automatic torque boost

Automatic torque boost can be realized through the VF control.

Speed search start

Smooth start without impact can be realized in the rotating motor.

Acceleration and deceleration curves

Line: S curve

Operation instruction

Three channels: Local machine / LED/LCD operation panel are externally introduced; control terminals; telecommunication

Frequency instruction

Five channels: Local machine / LED/LCD operation panel are externally introduced; external terminal analog; external terminal multi-speed; telecommunication; PID

Man- machine interface

Analog input

2 circuits, 0 - 10V or 0/4 -20mA optional, programmable

Analog output

2 circuits, 0 - 10V or 0/4 -20mA optional, programmable

Digital input

8 circuits, programmable

Digital output

2 circuits relay output signal, programmable 1 circuit open collector signal, programmable

Keyboard display

It supports the LCD display and digital display keyboard. Standard configuration: LCD screen display and keyboard, RJ 45 interface

Communication interface

It supports the Modbus-RTU or Profibus DP communication protocol. Standard configuration: Profibus DP protocol, DB9 interface.

 

Encoder Interface

It supports the 24V optical-electricity encoder collector open circuit and differential signals.

Extended board and card

Extensible communication board and card, which supports the Ethernet and wireless network.
Extensible PG board and card, which supports 5V sin-cos encoder, rotary transformer and other different encoder signals.
Extensible I/O board and card, which supports digital and analog input and output signals.

Protection function

Inverter Unit: Overcurrent, overvoltage, under voltage, motor overload, frequency inverter overload, output phase loss, overheated inverter module, drive breakdown and so on.

Environment

Place for use

Indoor, the altitude is lower than 1000 meters, no dust, no leakage, no corrosive gas, away from direct sunlight

Temperature for storage environment

-45 - +65℃

Operation temperature

-10 - +40℃
Degraded use for temperature between 40 - SOA. The rated output current shall be reduced by 1% for each one degree rise in temperature.

Humidity

5 - 95% (no condensation)

Altitude

0 -2000 meters,
Degraded use for height of over 1000 meters. The rated output current shall be reduced by 1% for each 100 meter rise in height.

Vibration

Less than 0.5g

Storage temperature

-40 - +70℃

Protection level

IP20

Advantages of Multi-drive System

 

Improved energy efficiency
With a multidrive solution you always save more energy compared to multiple single drives. Having multiple motors in an application where one machine is driving and at the same time another machine is braking it is possible to regenerate the power through the dc link. Therefore, losses in both rectifiers and both input transformers can be saved.

 

Reduced footprint
Using a VFD multidrive concept you always save some footprint. The savings can range from small (e.g. one module less) to significant. A multidrive with two motors might still use the same physical size of water cooling unit as the water cooling unit in each single drive.

 

Reduced rectifier and transformer size
Multidrive concept, as already mentioned, is perfectly suited to use power regenerated from one machine operated at given instant as generator and feed it to another machine operated as a motor. Their power balances nicely and there is very small power consumption from the grid just to cover losses of inverters and motors.

 

Reduced investment cost
Capital expenditures (CAPEX) of a multidrive are lower than equivalent sum of single drives. The savings can differ from few percent up to substantial portion of the investment.

 

Reduced operation cost
Operational expenditure (OPEX) is lower compared to individual drives due to better efficiency, resp. smarter power management. The maintenance cost is lower and the maintenance tasks are less time consuming. Certain components experience less cyclic loading due to dc bus regeneration leading to longer lifetime / slower aging.

 

 

Common types

High Speed Rewinding Machine
RENLE high speed rewinding machine drive control system driving system adopts a rectification feedback device, which feeds back the feedback energy of the paper return in real time to the power grid, thereby achieving the effect of energy conservation and consumption reduction! The structure of the system is basically the same as the paper machine drive, but the control requirements are higher than the paper machine drive system. Especially for the rapid acceleration and deceleration of the rewinding machine, very high control accuracy is required.

 

Drive For Paper Mills
RENLE's paper machine drive systems drive for paper mills deliver higher performance, greater energy efficiency, and superior product quality for paper manufacturers. Whether the drive system is applied to a paper machine, coater, calender, or winder, paper mills can expect quick start-up and high reliability. With its deep understanding of papermaking processes, RENLE provides drive solutions that can be seamlessly integrated with other automation systems in a paper mill.

Drive For Paper Mills manufacturers
Drives Used in Paper Mills manufacturers

 

Application

Pulp and Paper:
Control of multiple motors in paper machines for web tension control and synchronization.

 

Metals Industry:
Application in rolling mills and processing lines where precise coordination of many drives is crucial for high-quality production.

 

Mining, Oil, and Gas:
Control of conveyors, pumps, and other heavy machinery, where energy efficiency and load distribution are important.

 

Cranes and Ports:
Used in heavy-duty cranes for efficient material handling and coordinated movement.

 

Test Stands:
Often use multi-motor drives for complex, precisely controlled testing applications.

Customization Process

 

Requirement Discussion

Contact us and provide your design drawings, size specifications, and other technical parameters.

01

Design Proposal

Our professional team will develop a design proposal and provide a quotation based on your requirements.

02

Sample Production

We produce samples according to the design proposal and conduct rigorous testing.

03

Mass Production

Upon your approval, we commence mass production to ensure timely delivery and consistent quality.

04

After-Sales Service

We offer ongoing technical support and service to ensure the long-term stable operation of our products.

05

 

Package & Delivery

 

 

Package: Standard export package or Custom


Delivery: By air express, by sea

p202507081717564a719.jpg (800×730)

 

 

FAQ

 

Q: What is a multidrive?

A: Multidrive concept is a VFD solution where multiple motors are supplied and controlled from one VFD having several inverters connected to a common dc link. This concept has several advantages and is especially popular in certain applications, for instance rolling mill drives or specific test stands.

Q: What are the main components of a multi drive VFD?

A: Rectifier (AC to DC Conversion) ...
DC Bus (Storage and Smoothing) ...
Inverter (DC to AC Conversion) ...
Control Circuitry (Microprocessor/Controller) ...
Filter (Harmonic Filtering) ...
Cooling System. ...
Protection Circuitry. ...
User Interface (Display and Controls)

Q: How often should VFDs be serviced?

A: VFDs are designed to operate maintenance-free for a defined period of time, usually five to ten years of operating time, depending on the manufacturer and model. Larger VFDs are designed to be serviced as specific components age.

Q: Is it okay to put a disconnect between a VFD drive and the motor?

A: Note that the disconnect should not be opened or closed while the VFD is running (outputting voltage from T1,T2,T3). This is sometimes referred to as "slamming the motor." This can damage the output IGBT components of the drive and such damage is not covered under warranty.

Q: Are you manufacturer or trading company?

A: We are manufacturer.

Q: What's your best delivery time?

A: Within 15-30 days.

Q: What is the quality control of your product?

A: Follow strictly quality control measures for implementation,

Q: Will your company provide free sample?

A: It depends on which sort of item you want to get. Some can be provided free of charge, however, the client shall assume the shipping fees himself.

Q: Is OEM open to clients?

A: Yes, we can provide both OEM and ODM service.

Q: What is the payment of sample?

A: T/T and Alipay both acceptable.

Q: What is your packing?

A: Yes, our packaging is genuine original packaging. Of course, we can also provide neutral packaging or according to your requirements

Q: What is your sample policy?

A: If we have stock, we can provide samples, but the customer must pay the sample fee and express fee Question

Q: Have you tested all your goods before shipment?

A: Yes, we will conduct 100% test before delivery, and we will send detailed photos of parts for your approval Question .

We're well-known as one of the leading multi-drive system manufacturers and suppliers in China. Please feel free to buy customized multi-drive system made in China here from our factory. For pricelist and quotation, contact us now.