Medium Voltage Starter
video
Medium Voltage Starter

Medium Voltage Starter

The RENLE Intelligent Medium Voltage Soft Starter is designed for three-phase asynchronous and synchronous motors with voltage ratings from 3 kV to 13.8 kV and power ratings from 200 kW to 15 MW. Built with advanced thyristor control technology and fiber optic multiplexing technology, this medium voltage soft starter features a fully digital design and supports 5G industrial Ethernet communication for remote monitoring, remote operation, and online upgrades. RENLE intelligent medium voltage soft starters provide smooth soft start and soft stop, adjustable starting current and starting time, and multiple motor protection functions. With an IP4X protection rating, they are suitable for demanding industrial environments. The series is widely used for starting fans, pumps, compressors, and other motor-driven equipment in industries such as power generation, metallurgy, mining, petrochemical, cement, and water treatment. With reliable performance, flexible control, and intelligent remote maintenance, RENLE provides a professional medium voltage motor starting solution for heavy-duty industrial applications.

INTELLIGENT MEDIUM VOLTAGE STARTER

 

With the support of Industrial IoT and 5G technologies, and based on Renle's years of accumulated technological expertise, the medium-voltage power modules achieve full digitalization through optical fiber multiplexing technology. The newly developed intelligent soft starters are equipped with standard industrial Ethernet and a variety of communication interfaces. Using industrial Ethernet, the soft starter enables remote data analysis, software upgrades, debugging, a virtual oscilloscope, and other digital functions.

hv soft starter

RNMV-EI
INTELLIGENT-HIGH-VOLTAGE SOLID-STATE SOFT STARTER


• Optical fiber multiplexing technology

• Fully digital high-voltage power modules
• Multiple communication interfaces
• Supports 6 industrial Ethernet connections
• Remote data analysis
• Remote software upgrades

Data Visualization and Analysis

 

t(s)Real-time display of all data and operating status

 

 

By connecting the soft starter to the IT platform via a network protocol, motor data visualization is enabled through IT technology.

product-600-300

 

Making full use of the cloud platform's computing power enables online analysis and diagnosis of motor operating status, fault warning, and optimal control.

product-600-300

 

 

11 Connection to the cloud server provides data for big-data analysis and related artificial intelligence algorithms.

product-600-300

 

Main Body

 

  • The RNMV-EI is a solid-state medium voltage starter designed for three-phase induction motors. It manages motor acceleration, deceleration, and protection by regulating voltage through thyristor firing angle control. This enables smooth motor starts and stops, significantly reducing power supply inrush currents and minimizing mechanical stress on driven equipment and couplings. Consequently, the system mitigates electrical grid disturbances and safeguards mechanical components from shock loads.
  • Medium voltage systems bring inherent complexity-your starter shouldn't add more. RENLE's RNMV-EI medium voltage soft starter simplifies operation with intuitive features like plain-text diagnostics, eliminating cryptic code lookups. Integrated monitoring, status indicators, and comprehensive I/O minimize spatial demands and auxiliary costs while streamlining deployment. Live motor performance curves and current displays provide instant clarity on operational status. Experience effortless control: The RNMV-EI delivers clear operational feedback in everyday language, ensuring straightforward starts without decoding manuals.

 

Advantages

 

5G Industrial Ethernet Communication Technology

Based on industrial Ethernet and cloud platforms, the system enables comprehensive remote technical support for field equipment.

Data reading->waveform display->data diagnosis->software upgrade

 

Supports multiple communication protocols

1. Supports Modbus RTU, Modbus TCP, and PROFIBUS DP.

2. Provision of multiple interfaces facilitates parameter reading, writing, and data monitoring.

3. Supports remote waveform monitoring and data analysis via software.

4. Data downloads and software upgrades are performed via FTP and TFTP.

 

Application environment

 

product-512-512

Temperature

Cabinet temperature: 0°C to 40°C (optional heater available for -20°C to 0°C).
 

product-512-512 

Contact Information

Address: No. 101, Chunyi Road, Jiading District, Shanghai, China.
 

product-512-512

≤2000m 

Altitude

Applicable below 2000 m. Derating is necessary for altitudes above 2000 m.
 

product-512-512

Installation Location
Installed indoors, free of explosive or corrosive gases, and with low dust levels.

 

Applications

 

We are committed to supporting industrial more development by providing high-quality products.

 

The RNMV-EI medium-voltage starter can be applied in a wide range of industries, including electric power, metallurgy, petroleum, petrochemical, mining, building materials, chemical, and municipal engineering, providing a compact, stable, and reliable soft-starting solution for controlling medium-voltage motors.

Equipped with comprehensive motor and system protection functions, Renle's soft starters deliver dependable performance even in the harshest environments. With abundant user interfaces and a modular design, our intelligent soft starters meet the starting requirements of large and medium-sized industrial machinery across modern industries.

We are always ready to provide you with the right solution!

 

product-46-61

Electric power industry

product-66-61

Chemical industry

product-80-53

Coal industry

product-56-53

Paper industry

product-54-61

Steel industry

product-79-61

Petroleum Industry

product-66-61

Water conservancy industry

product-58-61

Machinery manufacturing

 

Model Description

product-1981-1161

 

Technical features

 

Thyristor valve group series connection and dual power supply triggering technology is adopted;

● Optical fiber communication multiplexing technology for precise drive control and data collection.

● HMI is adopted for real-time monitoring, display, modification, and set of system status and data.

● Equipped with OBD and software dual overvoltage protection functions.

● Statistics of valve group limit data are performed after each startup to evaluate the system status;

● With a phase-locked loop synchronously used, the three-phase conduction compensation technology controls the algorithm;

● Protections include: undervoltage, phase loss, overcurrent, overheating, thyristor overvoltage, triggering failure, abnormal voltage sharing, abnormal RC current, thyristor failure, optical fiber communication interruption, abnormal triggering power supply, etc. Start of the soft starter is prohibited when any abnormality is identified;

● Remote software update, commissioning, data waveform monitoring and fault analysis is realized through InterNet;

● After connecting to the cloud server through industrial Ethernet + 5G, the soft starter provides data for big data analy-sis and related AI algorithms, makes full use of the computing power of the cloud platform to realize online analysis and diagnosis of motor operating status, and realizes fault pre-warning and optimized control.

 

Medium Voltage Starter Functions

 

● Strong load adaptability with 2 start-up control modes:

① Constant current mode: The motor's starting current is limited to 100–500% of its rated value.

② Voltage ramp mode: The control angle causes the output voltage to increase linearly to the rated voltage.

● Either free stop or soft stop can be selected, suitable for different stopping conditions and meets specific needs - for example, eliminating the water hammer effect in water pumps.

 

Full digitalization of power modules

 

mv soft starter board

Ensure reliable operation of series thyristors

1. The triggering board is equipped with an MCU-based monitoring system, which records the status of the power modules during each startup.
2. It collects important data from the power modules at each level, including:
①Vrc voltage: Voltage across each RC group.
②Forward and reverse peak Vrc voltage: Forward and reverse peak voltages across each RC during soft starter startup.
③Control voltage: Average, maximum, and minimum control voltages for each group of positive triggering boards.
④RC current: Average current value for each RC group.
3. Standard SCR overvoltage self-triggering function and hardware and software dual settings, ensure the safety of SCR.

 

Technical Parameters

                                    

Data Name Working Range
Frequency 50Hz/60Hz±2Hz(selected according to user's grid)
Overload capacity 400% control nominal value 60s
500% control nominal value 30s
Applicable motor Three-phase squirrel-cage asynchronous and synchronous motor

 

Application environment

 

Temperature Cabinet temperature 0°C~40°C, (Heater is optional for -20°C~0°C)
Humidity 5%~95% relative humidity
Altitude Below 2000m. Derating is necessary for altitude above 2000m.
Place Indoors, no explosive or corrosive gas, with low dust
Cooling Natural cooling
Protection level IP4X

 

Structural features

 

Protection level IP4X
Operation power supply 2kVA AC220V supplied by the user (can be specified).
Main circuit The number of thyristors is determined by the model.
Communication protocol Integrated Modbus RTU, Modbus TCP, CAN and PROFIBUS DP communication protocols, equipped with interface.
Communication interface RJ45
Operation interface 7-inch touch screen (HMI) which monitors system status in real-time. Used for setting and modifying parameters.
Event record It can continuously record events and historical curves with time and date stamps within 10 days.
Performance monitoring Current, voltage, power factor, module temperature, RC average and peak voltage, RC current, etc.
Input and output options 10 channels of 24VDC programmable inputs, 2 channels of 16A and 4 channels of 5A programmable outputs, 1 analog programmable output (4~20mA).
User management Multi-level user password protection (can be specified).
Interface language Chinese, English, Russian (can be specified)
Thyristor Thyristor valve group in series
Drive and data Dual power supply triggering, optical fiber communication multiplexing technology;
Adopting synchronous phase-locked loop, three-phase conduction compensation algorithm;
Equipped with OBD and software double overvoltage function;
After startup is completed, the valve group limit data are counted for evaluating the system status.
Monitoring HMI window, used for real-time monitoring of system status, collection of valve group data and setting and modification of control parameters.
Protection Undervoltage, overvoltage, phase loss, overheating, abnormal voltage sharing, abnormal RC current, thyristor failure, optical fiber communication interruption, abnormal triggering power supply etc.
Cloud service Remote software update, commissioning, data waveform monitoring and fault analysis is realized through InterNet;
After connecting to the cloud server through industrial Ethernet + 5G, the soft starter provides data for big data analysis and related AI algorithms;
Makes full use of the computing power of the cloud platform to realize online analysis and diagnosis of motor operating status, and realizes fault pre-warning and optimized control.
Cabinet color Selected by the user.

 

Start data

 

Starting current Adjustable within 4 times of the rated current of the motor.
Starting time Adjustable within 10~60 seconds.
Number of starts 6 times per hour at an ambient temperature of 25°C.
Starting interval No less than 5 minutes between two starts.

 

Protection parameters

 

Transient overcurrent Protection range 200%~800%
Inverse time overcurrent The protection time is 1 minute for 1.5 times, used for protecting the motor during bypass operation.
Incoming line undervoltage Range: 0%~100%
Grounding Ground protection is identified by zero-sequence current.
Output phase loss Set the threshold 1.0%~50% according to the parameters by comparison of the three-phase output current.
Thyristor breakdown Set action threshold through parameters by monitoring voltage of each level of thyristors.
RC current Monitor RC current of each level of thyristors and identity RC working status. Current deviation can be set.
Trigger failure During startup, the number of triggering failure exceeds the set parameter value within 2 seconds of detection window, so protection acts.
Start timeout The start time exceeds the set value.
Triggering power If the power of the triggering board is lower or higher than the hardware protection value, protection of triggering board power acts.
Temperature SCR temperature exceeds the set parameters.
Thyristor overvoltage During the starting process, each level of SCR is equipped with OBD protection. During one starting process, the number of overvoltage automatic triggering reaches the set parameter, the protection is performed.

 

Structural features

product-500-800

Conventional type

Medium-voltage Solid-state Soft Starter

 

 

  Fiber multiplexing technology

  Full digitalization of mdedium-voltage power modulesVarious   communication interfaces

  Industrial Ethernet communication

  Remote data analysis

  Remote software upgrade

product-800-500

 

Medium Voltage Starter Selection Table

 

Valve group current

(A)

Voltage (kV)

Max. power of universal motor (kW)

Specifications

Cabinet dimensions (H×W×D,mm)

Weight (t)

150

3

630

RNMV-030150

2300*800*1500

0.7

150

3.3

650

RNMV-033150

2300*800*1500

0.7

150

6

1250

RNMV-060150

2300*800*1500

0.7

150

6.6

1350

RNMV-066150

2300*800*1500

0.7

150

10

2000

RNMV-100150

2300*800*1500

0.75

150

11

2240

RNMV-110150

2300*800*1500

0.75

330

3

1350

RNMV-030330

2300*1000*1500

0.78

330

3.3

1500

RNMV-033330

2300*1000*1500

0.78

330

6

2700

RNMV-060330

2300*1000*1500

0.8

330

6.6

3000

RNMV-066330

2300*1000*1500

0.8

330

10

4500

RNMV-100330

2300*1000*1500

0.8

330

11

5000

RNMV-110330

2300*1000*1500

0.8

500

3

2000

RNMV-030500

2300*1100*1500

0.85

500

3.3

2240

RNMV-033500

2300*1100*1500

0.85

500

6

4000

RNMV-060500

2300*1100*1500

0.85

500

6.6

4500

RNMV-066500

2300*1100*1500

0.85

500

10

6800

RNMV-100500

2300*1100*1500

1

500

11

7600

RNMV-110500

2300*1100*1500

1

700

3

2800

RNMV-030700

2300*1200*1500

1

700

3.3

3150

RNMV-033700

2300*1200*1500

1

700

6

5800

RNMV-060700

2300*1200*1500

1.2

700

6.6

6300

RNMV-066700

2300*1200*1500

1.2

700

10

9600

RNMV-100700

2300*1200*1500

1.25

700

11

10000

RNMV-110700

2300*1200*1500

1.25

1000

3

4000

RNMV-0301000

2300*1400*1500

1.5

1000

3.3

4500

RNMV-0331000

2300*1400*1500

1.5

1000

6

8200

RNMV-0601000

2300*1400*1500

1.8

1000

6.6

9100

RNMV-0661000

2300*1400*1500

1.8

1000

10

13500

RNMV-1001000

2300*1400*1500

1.8

1000

11

15000

RNMV-1101000

2300*1400*1500

1.8

 

product-500-800

Integrated cabinet Medium voltage

Solid-state Soft Starter

 

 

  Ffiber multiplexing technology

  Full digitalization of high voltage power modules

  Various communication interfaces

  industrial Ethernet communication

  Remote data analysis

  Remote software upgrade

product-800-500

 

Integrated Soft Starter Selection Table

 

Valve group current

(A)

Voltage (kV)

Max. power of universal motor (kW)

Specifications

Cabinet dimensions (H×W×D,mm)

Weight (t)

150

3

560

RNMV030150

2300*800*1500

0.7

150

3.3

630

RNMV033150

2300*800*1500

0.7

150

6

1250

RNMV060150

2300*800*1500

0.7

150

6.6

1350

RNMV066150

2300*800*1500

0.7

150

10

2000

RNMV100150

2300*800*1500

0.7

150

11

2240

RNMV100150

2300*800*1500

0.7

330

3

1350

RNMV030300

2300*1000*1500

0.85

330

3.3

1500

RNMV033300

2300*1000*1500

0.85

330

6

2700

RNMV060300

2300*1000*1500

0.85

330

6.6

3000

RNMV066300

2300*1000*1500

0.85

330

10

4500

RNMV100300

2300*1000*1500

0.85

330

11

5000

RNMV110300

2300*1000*1500

0.85

Hot Tags: medium voltage starter, China medium voltage starter manufacturers, suppliers, factory, Medium Voltage Solid State Starter, 6.6 kv soft starter, 3 phase soft starter, 4160v motor starter, vfd starter for motor, aircon soft starter