INTELLIGENT MEDIUM VOLTAGE STARTER
With the support of Industrial IoT and 5G technologies, and based on Renle's years of accumulated technological expertise, the medium-voltage power modules achieve full digitalization through optical fiber multiplexing technology. The newly developed intelligent soft starters are equipped with standard industrial Ethernet and a variety of communication interfaces. Using industrial Ethernet, the soft starter enables remote data analysis, software upgrades, debugging, a virtual oscilloscope, and other digital functions.
![]() |
RNMV-EI
• Fully digital high-voltage power modules |
Data Visualization and Analysis
t(s)Real-time display of all data and operating status
By connecting the soft starter to the IT platform via a network protocol, motor data visualization is enabled through IT technology.

Making full use of the cloud platform's computing power enables online analysis and diagnosis of motor operating status, fault warning, and optimal control.

11 Connection to the cloud server provides data for big-data analysis and related artificial intelligence algorithms.

Main Body
- The RNMV-EI is a solid-state medium voltage starter designed for three-phase induction motors. It manages motor acceleration, deceleration, and protection by regulating voltage through thyristor firing angle control. This enables smooth motor starts and stops, significantly reducing power supply inrush currents and minimizing mechanical stress on driven equipment and couplings. Consequently, the system mitigates electrical grid disturbances and safeguards mechanical components from shock loads.
- Medium voltage systems bring inherent complexity-your starter shouldn't add more. RENLE's RNMV-EI medium voltage soft starter simplifies operation with intuitive features like plain-text diagnostics, eliminating cryptic code lookups. Integrated monitoring, status indicators, and comprehensive I/O minimize spatial demands and auxiliary costs while streamlining deployment. Live motor performance curves and current displays provide instant clarity on operational status. Experience effortless control: The RNMV-EI delivers clear operational feedback in everyday language, ensuring straightforward starts without decoding manuals.
Advantages
5G Industrial Ethernet Communication Technology
Based on industrial Ethernet and cloud platforms, the system enables comprehensive remote technical support for field equipment.
Data reading->waveform display->data diagnosis->software upgrade
Supports multiple communication protocols
1. Supports Modbus RTU, Modbus TCP, and PROFIBUS DP.
2. Provision of multiple interfaces facilitates parameter reading, writing, and data monitoring.
3. Supports remote waveform monitoring and data analysis via software.
4. Data downloads and software upgrades are performed via FTP and TFTP.
Application environment

Temperature
Contact Information

≤2000m
Altitude

Installation Location
Installed indoors, free of explosive or corrosive gases, and with low dust levels.
Applications
We are committed to supporting industrial more development by providing high-quality products.
The RNMV-EI medium-voltage starter can be applied in a wide range of industries, including electric power, metallurgy, petroleum, petrochemical, mining, building materials, chemical, and municipal engineering, providing a compact, stable, and reliable soft-starting solution for controlling medium-voltage motors.
Equipped with comprehensive motor and system protection functions, Renle's soft starters deliver dependable performance even in the harshest environments. With abundant user interfaces and a modular design, our intelligent soft starters meet the starting requirements of large and medium-sized industrial machinery across modern industries.
We are always ready to provide you with the right solution!
|
Electric power industry |
Chemical industry |
Coal industry |
Paper industry |
Steel industry |
Petroleum Industry |
Water conservancy industry |
Machinery manufacturing |
Model Description

Technical features
Thyristor valve group series connection and dual power supply triggering technology is adopted;
● Optical fiber communication multiplexing technology for precise drive control and data collection.
● HMI is adopted for real-time monitoring, display, modification, and set of system status and data.
● Equipped with OBD and software dual overvoltage protection functions.
● Statistics of valve group limit data are performed after each startup to evaluate the system status;
● With a phase-locked loop synchronously used, the three-phase conduction compensation technology controls the algorithm;
● Protections include: undervoltage, phase loss, overcurrent, overheating, thyristor overvoltage, triggering failure, abnormal voltage sharing, abnormal RC current, thyristor failure, optical fiber communication interruption, abnormal triggering power supply, etc. Start of the soft starter is prohibited when any abnormality is identified;
● Remote software update, commissioning, data waveform monitoring and fault analysis is realized through InterNet;
● After connecting to the cloud server through industrial Ethernet + 5G, the soft starter provides data for big data analy-sis and related AI algorithms, makes full use of the computing power of the cloud platform to realize online analysis and diagnosis of motor operating status, and realizes fault pre-warning and optimized control.
Medium Voltage Starter Functions
● Strong load adaptability with 2 start-up control modes:
① Constant current mode: The motor's starting current is limited to 100–500% of its rated value.
② Voltage ramp mode: The control angle causes the output voltage to increase linearly to the rated voltage.
● Either free stop or soft stop can be selected, suitable for different stopping conditions and meets specific needs - for example, eliminating the water hammer effect in water pumps.
Full digitalization of power modules
|
|
Ensure reliable operation of series thyristors1. The triggering board is equipped with an MCU-based monitoring system, which records the status of the power modules during each startup. |
Technical Parameters
| Data Name | Working Range |
| Frequency | 50Hz/60Hz±2Hz(selected according to user's grid) |
| Overload capacity | 400% control nominal value 60s |
| 500% control nominal value 30s | |
| Applicable motor | Three-phase squirrel-cage asynchronous and synchronous motor |
Application environment
| Temperature | Cabinet temperature 0°C~40°C, (Heater is optional for -20°C~0°C) |
| Humidity | 5%~95% relative humidity |
| Altitude | Below 2000m. Derating is necessary for altitude above 2000m. |
| Place | Indoors, no explosive or corrosive gas, with low dust |
| Cooling | Natural cooling |
| Protection level | IP4X |
Structural features
| Protection level | IP4X |
| Operation power supply | 2kVA AC220V supplied by the user (can be specified). |
| Main circuit | The number of thyristors is determined by the model. |
| Communication protocol | Integrated Modbus RTU, Modbus TCP, CAN and PROFIBUS DP communication protocols, equipped with interface. |
| Communication interface | RJ45 |
| Operation interface | 7-inch touch screen (HMI) which monitors system status in real-time. Used for setting and modifying parameters. |
| Event record | It can continuously record events and historical curves with time and date stamps within 10 days. |
| Performance monitoring | Current, voltage, power factor, module temperature, RC average and peak voltage, RC current, etc. |
| Input and output options | 10 channels of 24VDC programmable inputs, 2 channels of 16A and 4 channels of 5A programmable outputs, 1 analog programmable output (4~20mA). |
| User management | Multi-level user password protection (can be specified). |
| Interface language | Chinese, English, Russian (can be specified) |
| Thyristor | Thyristor valve group in series |
| Drive and data | Dual power supply triggering, optical fiber communication multiplexing technology; |
| Adopting synchronous phase-locked loop, three-phase conduction compensation algorithm; | |
| Equipped with OBD and software double overvoltage function; | |
| After startup is completed, the valve group limit data are counted for evaluating the system status. | |
| Monitoring | HMI window, used for real-time monitoring of system status, collection of valve group data and setting and modification of control parameters. |
| Protection | Undervoltage, overvoltage, phase loss, overheating, abnormal voltage sharing, abnormal RC current, thyristor failure, optical fiber communication interruption, abnormal triggering power supply etc. |
| Cloud service | Remote software update, commissioning, data waveform monitoring and fault analysis is realized through InterNet; |
| After connecting to the cloud server through industrial Ethernet + 5G, the soft starter provides data for big data analysis and related AI algorithms; | |
| Makes full use of the computing power of the cloud platform to realize online analysis and diagnosis of motor operating status, and realizes fault pre-warning and optimized control. | |
| Cabinet color | Selected by the user. |
Start data
| Starting current | Adjustable within 4 times of the rated current of the motor. |
| Starting time | Adjustable within 10~60 seconds. |
| Number of starts | 6 times per hour at an ambient temperature of 25°C. |
| Starting interval | No less than 5 minutes between two starts. |
Protection parameters
| Transient overcurrent | Protection range 200%~800% |
| Inverse time overcurrent | The protection time is 1 minute for 1.5 times, used for protecting the motor during bypass operation. |
| Incoming line undervoltage | Range: 0%~100% |
| Grounding | Ground protection is identified by zero-sequence current. |
| Output phase loss | Set the threshold 1.0%~50% according to the parameters by comparison of the three-phase output current. |
| Thyristor breakdown | Set action threshold through parameters by monitoring voltage of each level of thyristors. |
| RC current | Monitor RC current of each level of thyristors and identity RC working status. Current deviation can be set. |
| Trigger failure | During startup, the number of triggering failure exceeds the set parameter value within 2 seconds of detection window, so protection acts. |
| Start timeout | The start time exceeds the set value. |
| Triggering power | If the power of the triggering board is lower or higher than the hardware protection value, protection of triggering board power acts. |
| Temperature | SCR temperature exceeds the set parameters. |
| Thyristor overvoltage | During the starting process, each level of SCR is equipped with OBD protection. During one starting process, the number of overvoltage automatic triggering reaches the set parameter, the protection is performed. |
Structural features
|
|
Conventional typeMedium-voltage Solid-state Soft Starter
Fiber multiplexing technology Full digitalization of mdedium-voltage power modulesVarious communication interfaces Industrial Ethernet communication Remote data analysis Remote software upgrade |
|
|
|
Medium Voltage Starter Selection Table
|
Valve group current (A) |
Voltage (kV) |
Max. power of universal motor (kW) |
Specifications |
Cabinet dimensions (H×W×D,mm) |
Weight (t) |
|
150 |
3 |
630 |
RNMV-030150 |
2300*800*1500 |
0.7 |
|
150 |
3.3 |
650 |
RNMV-033150 |
2300*800*1500 |
0.7 |
|
150 |
6 |
1250 |
RNMV-060150 |
2300*800*1500 |
0.7 |
|
150 |
6.6 |
1350 |
RNMV-066150 |
2300*800*1500 |
0.7 |
|
150 |
10 |
2000 |
RNMV-100150 |
2300*800*1500 |
0.75 |
|
150 |
11 |
2240 |
RNMV-110150 |
2300*800*1500 |
0.75 |
|
330 |
3 |
1350 |
RNMV-030330 |
2300*1000*1500 |
0.78 |
|
330 |
3.3 |
1500 |
RNMV-033330 |
2300*1000*1500 |
0.78 |
|
330 |
6 |
2700 |
RNMV-060330 |
2300*1000*1500 |
0.8 |
|
330 |
6.6 |
3000 |
RNMV-066330 |
2300*1000*1500 |
0.8 |
|
330 |
10 |
4500 |
RNMV-100330 |
2300*1000*1500 |
0.8 |
|
330 |
11 |
5000 |
RNMV-110330 |
2300*1000*1500 |
0.8 |
|
500 |
3 |
2000 |
RNMV-030500 |
2300*1100*1500 |
0.85 |
|
500 |
3.3 |
2240 |
RNMV-033500 |
2300*1100*1500 |
0.85 |
|
500 |
6 |
4000 |
RNMV-060500 |
2300*1100*1500 |
0.85 |
|
500 |
6.6 |
4500 |
RNMV-066500 |
2300*1100*1500 |
0.85 |
|
500 |
10 |
6800 |
RNMV-100500 |
2300*1100*1500 |
1 |
|
500 |
11 |
7600 |
RNMV-110500 |
2300*1100*1500 |
1 |
|
700 |
3 |
2800 |
RNMV-030700 |
2300*1200*1500 |
1 |
|
700 |
3.3 |
3150 |
RNMV-033700 |
2300*1200*1500 |
1 |
|
700 |
6 |
5800 |
RNMV-060700 |
2300*1200*1500 |
1.2 |
|
700 |
6.6 |
6300 |
RNMV-066700 |
2300*1200*1500 |
1.2 |
|
700 |
10 |
9600 |
RNMV-100700 |
2300*1200*1500 |
1.25 |
|
700 |
11 |
10000 |
RNMV-110700 |
2300*1200*1500 |
1.25 |
|
1000 |
3 |
4000 |
RNMV-0301000 |
2300*1400*1500 |
1.5 |
|
1000 |
3.3 |
4500 |
RNMV-0331000 |
2300*1400*1500 |
1.5 |
|
1000 |
6 |
8200 |
RNMV-0601000 |
2300*1400*1500 |
1.8 |
|
1000 |
6.6 |
9100 |
RNMV-0661000 |
2300*1400*1500 |
1.8 |
|
1000 |
10 |
13500 |
RNMV-1001000 |
2300*1400*1500 |
1.8 |
|
1000 |
11 |
15000 |
RNMV-1101000 |
2300*1400*1500 |
1.8 |
|
|
Integrated cabinet Medium voltage Solid-state Soft Starter
Ffiber multiplexing technology Full digitalization of high voltage power modules Various communication interfaces industrial Ethernet communication Remote data analysis Remote software upgrade |
|
|
|
Integrated Soft Starter Selection Table
|
Valve group current (A) |
Voltage (kV) |
Max. power of universal motor (kW) |
Specifications |
Cabinet dimensions (H×W×D,mm) |
Weight (t) |
|
150 |
3 |
560 |
RNMV030150 |
2300*800*1500 |
0.7 |
|
150 |
3.3 |
630 |
RNMV033150 |
2300*800*1500 |
0.7 |
|
150 |
6 |
1250 |
RNMV060150 |
2300*800*1500 |
0.7 |
|
150 |
6.6 |
1350 |
RNMV066150 |
2300*800*1500 |
0.7 |
|
150 |
10 |
2000 |
RNMV100150 |
2300*800*1500 |
0.7 |
|
150 |
11 |
2240 |
RNMV100150 |
2300*800*1500 |
0.7 |
|
330 |
3 |
1350 |
RNMV030300 |
2300*1000*1500 |
0.85 |
|
330 |
3.3 |
1500 |
RNMV033300 |
2300*1000*1500 |
0.85 |
|
330 |
6 |
2700 |
RNMV060300 |
2300*1000*1500 |
0.85 |
|
330 |
6.6 |
3000 |
RNMV066300 |
2300*1000*1500 |
0.85 |
|
330 |
10 |
4500 |
RNMV100300 |
2300*1000*1500 |
0.85 |
|
330 |
11 |
5000 |
RNMV110300 |
2300*1000*1500 |
0.85 |
Hot Tags: medium voltage starter, China medium voltage starter manufacturers, suppliers, factory, Medium Voltage Solid State Starter, 6.6 kv soft starter, 3 phase soft starter, 4160v motor starter, vfd starter for motor, aircon soft starter