Product Overview
Addressing retrofit needs while reducing capital expenditure and project timelines for new installations, the system features a unified architecture that incorporates transformer, power conversion, control, and high-voltage switchgear (with optional bypass) cabinets-all including internal wiring and components.
Installation requires only the connection of HV input/output cables, LV control power, and signal lines.
The RNHV series high voltage drive enables consolidated transport and front-access servicing, streamlining field setup, maintenance, and commissioning. Its DC bus uses metallized film capacitors with integrated mechanical bypass modules, offering enhanced reliability, zero maintenance, and an extended service life compared to electrolytic alternatives. Advanced protection and control capabilities ensure adaptable performance across diverse operating environments, meeting precise speed regulation requirements for industrial processes.
Product Features
RNHV2000 series High Voltage Drive
- Output Power: Maximum power of 10kV/14,000kW and 6kV/8,000kW.
- Standard Industrial Design: Supports various voltage levels ranging from 3kV to 13.8kV, suitable for high-altitude, low-temperature, and high-humidity applications.
- Customization for Customers: Offers customizable functionality and appearance to meet diverse customer requirements.
- Inverter Type: Voltage-source cascaded multilevel technology with no special requirements for motors or cables, achieving harmonic-free operation without the need for filters. The direct power supply distance can reach up to 1000m.
- Siemens PLC: Provides safe and reliable precise logic control with standard industrial interfaces.

Model Description

The components of the RNHV2000 Series

Power Unit Cabinet
Innovative Modular Drawer Cabinet Structure The new cabinet design features a modular drawer structure, allowing for quick plug-and-play connections, as well as convenient installation and maintenance. It combines innovative aesthetics with a lightweight and visually appealing design. |
Power Unit
H-Bridge Topology Structure: Modular design with interchangeable units. Semi-sealed structure offering strong environmental adaptability and high reliability. Integrated unit with an internal bypass function. |

Perfect Input-output Waveform

![]() |
![]() |
High-quality input waveform |
Perfect output waveform |
|
|
Energy-saving and Consumption Reduction
According to the load characteristic curve, the energy consumption of fans, pumps, and compressors is directly proportional to the cube of the motor speed. For these types of loads, controlling the motor speed is the most effective way to achieve energy savings.
According to the load characteristic curve, the energy consumption of fans, pumps, and compressors is directly proportional to the cube of the motor speed. For these types of loads, controlling the motor speed is the most effective way to achieve energy savings.
High voltage drive: By employing more precise, faster, and more flexible motor speed control methods, the overall level of process control can be significantly improved.
Variable frequency drives (VFDs) have the features of soft starters, which reduce the impact of high currents during motor startup on the power grid (voltage drop). Additionally, compared to soft starters, VFDs can provide greater starting torque and lower starting current, resulting in a more significant reduction in motor winding stress and energy consumption.
The motor startup and acceleration processes can be effectively controlled, reducing mechanical stress on the user's load.
Compared to operating at the motor's rated frequency, using VFDs results in a higher input power factor.
VFD energy losses can be as low as 1.5%(excluding transformers)

High Reliability
When selecting unit DC capacitors, we choose dry-type metallized electrolytic film capacitors, whereas traditional inverters commonly use aluminum electrolytic capacitors.
The DC capacitors serve to fully isolate the grid from the load through the inverter, eliminating voltage ripple, stabilizing DC voltage, and effectively suppressing disturbances caused by load and grid-side harmonics, as well as switch transients. This results in a longer mean time between failures (MTBF) and improved reliability.
The advantages of using metallized thin film capacitors are as follows:
- High ripple current handling capability.
- With their self-repair capabilities, they offer a longer lifespan.
- Outstanding performance in low temperatures.
- Operate at high voltage without the need for series connections or polarity, simplifying system design, reducing the impact of stray parameters, and enhancing system stability.
Product Technical Specifications
| Name | Item | Specification | |||||||||
| Input | 2000 Series Power Supply |
3-phase, 3.3~11kV, frequency: 50/60Hz | |||||||||
| Input voltage range | Voltage: -10% to +10%; Frequency: ±2% | ||||||||||
| Output | 2000 Series Rated Voltage |
3-phase 3.3~11kV, frequency: 50/60Hz | |||||||||
| Frequency modulation range |
0~50/60Hz | ||||||||||
| Setting resolution | 0.01 Hz | ||||||||||
| Overcurrent capability |
120% of rated output current for 1 minute every 10 minutes; 150% of rated output current for instantaneous protection. |
||||||||||
| Control | Control method | V/F control with PG vector control and without PG vector control. | |||||||||
| Synchronous switching |
The frequency converter follows the voltage phase and frequency of the power grid, achieving a state of grid connection and smooth switching from frequency converter to power frequency without impact |
||||||||||
| Torque compensation |
Automatic torque boost during startup to reach above 150%. | ||||||||||
| Slip compensation | Compensates for speed drop under load to enhance mechanical robustness. | ||||||||||
| Upper and lower frequency limits |
Upper and lower frequency limits can be set. | ||||||||||
| Skip frequency | Skip frequency can be set in 3 groups. | ||||||||||
Connect the table
| Name | Item | Specification | |||
| Control | Speed tracking during restart |
The inverter can automatically search for the motor speed and smoothly restart operation when the motor is coasting due to power loss. |
|||
| Acceleration and deceleration time |
Acceleration and deceleration time can be independently set from 0.1 to 3600 seconds. | ||||
| Acceleration and deceleration profile types |
Linear or S-curve profiles can be selected to meet various application requirements. | ||||
| Operating modes | Local operation, on-site operation, remote operation. | ||||
| Stopping methods | Option to choose between coasting stop or deceleration stop. | ||||
| PID closed-loop control |
Can be applied to various closed-loop control systems such as flow, pressure, temperature, and more. |
||||
| Neutral drift | By bypassing a power unit and using neutral drift technology, the three-phase output stays balanced. This guarantees maximum output power even after bypassing a unit. In case of a single-unit failure, the system can operate in bypass mode without impacting regular production operations. |
||||
| Automatic unit bypass |
When a unit malfunctions, the inverter can automatically bypass the faulty unit and continue oper- ating using neutral drift technology without the need for manual intervention. If more than two units are bypassed, users simply need to operate at a reduced capacity as necessary. |
||||
| Power failure restart |
In the event of an abnormal power outage, the inverter can automatically restart and restore to its pre-power loss state once the grid is restored within the set time, without the need for manual intervention. |
||||
| Frequency setting | Analog input signal setting: Configurable via a 4-20mA current signal. Multiple frequency segment selection settings. |
||||
| Fieldbus | ModbusđTcp/ipaPROFIBUS-DP | ||||
| Operating state output signal |
Relay output: selectable to indicate operating states such as running, stopped, fault, etc. Analog output: selectable to indicate operating parameters such as frequency, current, voltage, speed, etc. |
||||
| Display | During opera- tion/stop |
Display frequency, current, voltage, etc. | |||
| During setting | Display the set menu number or set parameter value | ||||
| During functional operation |
Display active function information or prompts. | ||||
| During alarms, faults |
Display various alarms and faults. | ||||
| Overload protection | To monitor the output current of the inverter and protect the inverter in case of overload. | ||||
| Protection | |||||
| Overvoltage protection |
To detect the overvoltage of the DC busbar unit and protect the inverter in case of input overvolt- age. |
||||
| Surge voltage protection |
To monitor surge voltages between input power lines and line-to-ground, protecting the inverter. | ||||
| Under-voltage protection |
To monitor the input voltage and protect the inverter in case of under-voltage. | ||||
| Overheat protection | To monitor the temperature rise of the heat sink and protect the inverter when it exceeds the set value. |
||||
| Short-circuit protection |
To monitor short circuits or overcurrent on the output side of the inverter, protecting the inverter. | ||||
| Motor overload protection |
To monitor the motor for overload during operation and protect the motor. | ||||
| Open phase protection |
To monitor the input voltage for phase loss and protect the inverter. | ||||
| Environment | Place of use | Indoors, at an altitude below 1000 meters, with no corrosive or flammable gases; free from dust, oil mist, water droplets, etc., preventing direct sunlight exposure, and without strong magnetic field interference. Altitudes above 1000 meters require derating for use. |
|||
| Operating temperature |
- 5℃~ +40℃ | ||||
| Operating humidity | 5 ~ 95%RH (non-condensing) | ||||
| Vibration | ≤0.5g | ||||
| Storage tempera- ture |
- 40℃~+70℃ | ||||
| Ingress protection rating |
IP30 (Please specify other protection ratings when ordering) | ||||
RNHV2000 Product Selection Table Ⅰ
| Inverter model | Rated voltage (kV) |
Rated current (A) |
Motor power compatibility (kW) |
Output capacity (kVA) |
Dimensions (W*D*H mm) (including fan) |
Weight (kg) |
||||||||
| 10kV | ||||||||||||||
| RNHV-A-10/220 | 10 | 16 | 220 | 280 | 3400*1200*2750 | 3350 | ||||||||
| RNHV-A-10/250 | 10 | 18 | 250 | 315 | 3380 | |||||||||
| RNHV-A-10/280 | 10 | 20 | 280 | 350 | 3400 | |||||||||
| RNHV-A-10/315 | 10 | 23 | 315 | 400 | 3420 | |||||||||
| RNHV-A-10/355 | 10 | 26 | 355 | 450 | 3440 | |||||||||
| RNHV-A-10/400 | 10 | 30 | 400 | 500 | 3460 | |||||||||
| RNHV-A-10/450 | 10 | 32 | 450 | 560 | 3480 | |||||||||
| RNHV-A-10/500 | 10 | 35 | 500 | 630 | 3500 | |||||||||
| RNHV-A-10/560 | 10 | 40 | 560 | 700 | 3600 | |||||||||
| RNHV-A-10/630 | 10 | 45 | 630 | 800 | 3600*1200*2750 | 3650 | ||||||||
| RNHV-A-10/710 | 10 | 50 | 710 | 900 | 3700 | |||||||||
| RNHV-A-10/800 | 10 | 60 | 800 | 1000 | 3800 | |||||||||
| RNHV-A-10/900 | 10 | 65 | 900 | 1120 | 3800*1500*2750 | 4200 | ||||||||
| RNHV-A-10/1000 | 10 | 75 | 1000 | 1250 | 4600 | |||||||||
| RNHV-A-10/1120 | 10 | 85 | 1120 | 1400 | 4800 | |||||||||
| RNHV-A-10/1250 | 10 | 90 | 1250 | 1600 | 5000 | |||||||||
| RNHV-A-10/1400 | 10 | 100 | 1400 | 1750 | 5200 | |||||||||
| RNHV-A-10/1600 | 10 | 115 | 1600 | 2000 | 5300 | |||||||||
| RNHV-A-10/1800 | 10 | 130 | 1800 | 2250 | 5500 | |||||||||
| RNHV-A-10/2000 | 10 | 145 | 2000 | 2500 | 4900*1500*2750 | 6400 | ||||||||
| RNHV-A-10/2100 | 10 | 150 | 2100 | 2650 | 6600 | |||||||||
| RNHV-A-10/2200 | 10 | 160 | 2200 | 2750 | 6800 | |||||||||
| RNHV-A-10/2240 | 10 | 165 | 2240 | 2800 | 7000 | |||||||||
| RNHV-A-10/2400 | 10 | 170 | 2400 | 3000 | 7200 | |||||||||
| RNHV-A-10/2500 | 10 | 180 | 2500 | 3150 | 7400 | |||||||||
| RNHV-A-10/2800 | 10 | 200 | 2800 | 3500 | 7600 | |||||||||
| RNHV-A-10/3000 | 10 | 215 | 3000 | 3750 | 7800 | |||||||||
| RNHV-A-10/3150 | 10 | 225 | 3150 | 3940 | 8000 | |||||||||
| RNHV-A-10/3550 | 10 | 250 | 3550 | 4500 | 5700*1700*2750 | 10000 | ||||||||
| RNHV-A-10/3800 | 10 | 275 | 3800 | 4750 | 10200 | |||||||||
| RNHV-A-10/4000 | 10 | 280 | 4000 | 5000 | 5900*1700*2750 | 10400 | ||||||||
| RNHV-A-10/4200 | 10 | 300 | 4200 | 5250 | 10600 | |||||||||
| RNHV-A-10/4400 | 10 | 315 | 4400 | 5500 | 10800 | |||||||||
| RNHV-A-10/4500 | 10 | 320 | 4500 | 5600 | 11000 | |||||||||
| RNHV-A-10/4800 | 10 | 350 | 4800 | 6000 | 6900*1700*3200 | 14300 | ||||||||
| RNHV-A-10/5000 | 10 | 360 | 5000 | 6250 | 14400 | |||||||||
| RNHV-A-10/5400 | 10 | 390 | 5400 | 6750 | 14500 | |||||||||
| RNHV-A-10/5600 | 10 | 400 | 5600 | 7000 | 14600 | |||||||||
| RNHV-A-10/6000 | 10 | 435 | 6000 | 7500 | 14700 | |||||||||
| RNHV-A-10/6300 | 10 | 460 | 6300 | 8000 | 14800 | |||||||||
| RNHV-A-10/7100 | 10 | 520 | 7100 | 9000 | 8200*1700*3200 | 16500 | ||||||||
| RNHV-A-10/8000 | 10 | 580 | 8000 | 10000 | 16800 | |||||||||
| RNHV-A-10/8500 | 10 | 600 | 8500 | 10625 | 17000 | |||||||||
| RNHV-A-10/9000 | 10 | 650 | 9000 | 11250 | 8400*1700*3500 | 22000 | ||||||||
| RNHV-A-10/9500 | 10 | 680 | 9500 | 11875 | 22200 | |||||||||
| RNHV-A-10/10000 | 10 | 710 | 10000 | 12500 | 22400 | |||||||||
| RNHV-A-10/10500 | 10 | 750 | 10500 | 13125 | 22600 | |||||||||
| RNHV-A-10/11000 | 10 | 780 | 11000 | 13750 | 26500 | |||||||||
| RNHV-A-10/11500 | 10 | 820 | 11500 | 14375 | 12400*1700*3500 | 26700 | ||||||||
| RNHV-A-10/12000 | 10 | 860 | 12000 | 15000 | 26900 | |||||||||
| RNHV-A-10/12500 | 10 | 900 | 12500 | 15600 | 27000 | |||||||||
| RNHV-A-10/14000 | 10 | 1000 | 14000 | 17500 | 27500 | |||||||||
RNHV2000 Product Selection Table Ⅱ
| Inverter model | Rated voltage (kV) |
Rated current (A) |
Motor power compatibility (kW) |
Output capacity (kVA) |
Dimensions (W*D*H mm) (including fan) |
Weight (kg) |
|||||||||||
| 6kV | |||||||||||||||||
| RNHV-A-6/220 | 6 | 26 | 220 | 280 | 2800*1200*2750 | 2850 | |||||||||||
| RNHV-A-6/250 | 6 | 30 | 250 | 315 | 2860 | ||||||||||||
| RNHV-A-6/280 | 6 | 35 | 280 | 350 | 2880 | ||||||||||||
| RNHV-A-6/315 | 6 | 40 | 315 | 400 | 2900 | ||||||||||||
| RNHV-A-6/355 | 6 | 45 | 355 | 450 | 2920 | ||||||||||||
| RNHV-A-6/400 | 6 | 50 | 400 | 500 | 2940 | ||||||||||||
| RNHV-A-6/450 | 6 | 55 | 450 | 560 | 2960 | ||||||||||||
| RNHV-A-6/500 | 6 | 60 | 500 | 630 | 2980 | ||||||||||||
| RNHV-A-6/560 | 6 | 70 | 560 | 700 | 3000*1200*2750 | 3000 | |||||||||||
| RNHV-A-6/630 | 6 | 75 | 630 | 800 | 3500 | ||||||||||||
| RNHV-A-6/710 | 6 | 85 | 710 | 900 | 3600 | ||||||||||||
| RNHV-A-6/800 | 6 | 100 | 800 | 1000 | 3700 | ||||||||||||
| RNHV-A-6/900 | 6 | 110 | 900 | 1120 | 3800 | ||||||||||||
| RNHV-A-6/1000 | 6 | 120 | 1000 | 1250 | 3900 | ||||||||||||
| RNHV-A-6/1120 | 6 | 130 | 1120 | 1400 | 4000 | ||||||||||||
| RNHV-A-6/1250 | 6 | 150 | 1250 | 1600 | 3800*1500*2800 | 4700 | |||||||||||
| RNHV-A-6/1400 | 6 | 170 | 1400 | 1800 | 5000 | ||||||||||||
| RNHV-A-6/1480 | 6 | 180 | 1480 | 1850 | 5200 | ||||||||||||
| RNHV-A-6/1600 | 6 | 190 | 1600 | 2000 | 5300 | ||||||||||||
| RNHV-A-6/1800 | 6 | 215 | 1800 | 2250 | 5500 | ||||||||||||
| RNHV-A-6/2000 | 6 | 240 | 2000 | 2500 | 4600*1500*2800 | 7000 | |||||||||||
| RNHV-A-6/2100 | 6 | 250 | 2100 | 2650 | 7200 | ||||||||||||
| RNHV-A-6/2200 | 6 | 265 | 2200 | 2750 | 7400 | ||||||||||||
| RNHV-A-6/2240 | 6 | 270 | 2240 | 2800 | 7600 | ||||||||||||
| RNHV-A-6/2400 | 6 | 275 | 2400 | 3000 | 7800 | ||||||||||||
| RNHV-A-6/2500 | 6 | 305 | 2500 | 3150 | 8000 | ||||||||||||
| RNHV-A-6/2800 | 6 | 340 | 2800 | 3500 | 5100*1700*2950 | 8200 | |||||||||||
| RNHV-A-6/3000 | 6 | 360 | 3000 | 3750 | 8400 | ||||||||||||
| RNHV-A-6/3150 | 6 | 380 | 3150 | 3940 | 8600 | ||||||||||||
| RNHV-A-6/3550 | 6 | 430 | 3550 | 4500 | 8800 | ||||||||||||
| RNHV-A-6/3800 | 6 | 470 | 3800 | 4750 | 9000 | ||||||||||||
| RNHV-A-6/4000 | 6 | 480 | 4000 | 5000 | 9200 | ||||||||||||
| RNHV-A-6/4200 | 6 | 505 | 4200 | 5250 | 6600*1700*2950 | 10700 | |||||||||||
| RNHV-A-6/4400 | 6 | 530 | 4400 | 5500 | 10900 | ||||||||||||
| RNHV-A-6/4500 | 6 | 540 | 4500 | 5600 | 11100 | ||||||||||||
| RNHV-A-6/4800 | 6 | 580 | 4800 | 6000 | 6900*1700*3200 | 11500 | |||||||||||
| RNHV-A-6/5000 | 6 | 600 | 5000 | 6300 | 12000 | ||||||||||||
| RNHV-A-6/5400 | 6 | 645 | 5400 | 6750 | 6000*1700*3400 | 14600 | |||||||||||
| RNHV-A-6/5600 | 6 | 675 | 5600 | 7000 | 14800 | ||||||||||||
| RNHV-A-6/6000 | 6 | 725 | 6000 | 7500 | 15000 | ||||||||||||
| RNHV-A-6/6300 | 6 | 750 | 6300 | 8000 | 8000*1700*3400 | 18600 | |||||||||||
| RNHV-A-6/7100 | 6 | 860 | 7100 | 9000 | 18800 | ||||||||||||
| RNHV-A-6/8000 | 6 | 900 | 8000 | 10000 | 19000 | ||||||||||||
The system specifications are shown in the table above. Please note that the dimensions may vary slightly from the actual size and are provided for equipment selection reference only. For the exact dimensions, please consult our sales personnel.
Application Areas
|
|
Power plant
Wind turbine / Compressor / Pumped hydro storage plant / Draft fan / Condensate pump / Circulating water pump / Boiler feedwater pump, etc. |
|
|
Oil, Petrochemicals, Natural gas
Pipeline transfer pump / Injection pump / Feedwater pump / Submers- ible oil pump / Circulating water pump / Brine pump / Compressor / Booster fan / Oil transfer pump / Electric submersible pump, etc. |
![]() |
Coal, Mining
Scale removal pump / Slurry pump / Slag slurry pump / Clear water pump / Feed pump / Axial flow fan / Agitation pump / Kiln / Transmis- sion / Dust removal fan / Drainage pump / Media pump / Counter-ro- tating fan, etc. |
![]() |
Cement building materials
Kiln induced draft fan / Kiln forced draft fan / Kiln tail fan / Kiln head fan / High-temperature fan / Coal mill fan / Dust removal fan / Circu lating fan / Raw material grinding fan / Cement grinding fan / Separa- tor fan / Pressure conveying fan, etc. |
![]() |
Steel and metallurgy
Blast furnace blower / induced draft fan / compression fan / air supply fan / feedwater pump / water supply pump / descaling pump / dust removal fan / converter / blast furnace / etc. |
![]() |
Municipal water supply
Aeration blower(for heating, water supply, sewage, etc.) / induced draft fan / air supply fan / booster pump / hot water circulation pump / sewage pump / clean water pump / lift pump / water supply pump / reclaimed water pump, etc. |
![]() |
Light industry, Chemical industry
Coal gas blower / booster pump / compressor / axial flow pump / soft water pump / water supply pump, etc. |
Hot Tags: high voltage drive, China high voltage drive manufacturers, suppliers, factory, inverter variable speed drive, diy vfd, ac vvvf drive, variable frequency drive inverter, 240v 60hz inverter, dc variable frequency drive