Model Description
The letters and numbers on the nameplate indicate the product series, power, applicable load type and so on.
R N B 1 X X X G / X X X P
X

Specialized Machine Code
Power Code 1000 Series
Variable Frequency Drive
Shanghai RENLE Science & Technology Co., Ltd.
|
Character |
Description |
|
RN |
Shanghai RENLE Science & Technology Co., Ltd. |
|
B |
Low-voltage Variable Frequency Drive |
|
1 |
1000 Series |
|
XXXG/XXXP |
Power Code: G: Constant torque load (Heavy load) P: Variable torque load (light load) G/P: G/P-model in one XXX: Power code: such as 001: 1.5kW; 037: 37kW; 110: 110kW |
|
-X |
Specialized machine code: No code indicates universal model -2S: Single-phase 220VAC input, Three-phase 220VAC output; -2SS: Single-phase 220VAC input, Single-phase 220VAC output. |
Achieve rapid deployment and intuitive operation for enhanced productivity.
The cabinet-ready, space-saving RNB1000 low voltage drive provides essential functionalities out of the box. Its streamlined setup menu and guided tools facilitate swift installation, configuration, operation, and servicing.
Designed to boost operational effectiveness and ease across diverse applications
The RNB1000 LV VFD integrates features that simplify drive selection and minimize reliance on additional components. Optimized for both variable torque and basic constant torque applications, it prioritizes a straightforward design, dependable performance, and energy savings. The drive's intuitive interface accelerates startup and commissioning.
Technical data
Enhanced operational efficiency and seamless integration across diverse industrial environments, leveraging integrated functionalities to streamline installation, tuning, and runtime.
- Up to 500 kW
- Wide power range from 0.75 kW
- Up to 480 V
- Wide voltage range from 220 V
Key benefits
- V/F Control Mode: Effectively protects the drive.
- Vector Control Mode: High-precision torque limiting control.
- V/F Separation Control Mode: The output frequency and output voltage can be set separately, making it suitable for various applications, such as variable frequency power supplies.
- Newly designed panel keyboard with superior operability, supporting dual-row display.
Product Feature
The RNB1000 series Low Voltage Drive VFD improves production efficiency for the majority of users through its compact structure, powerful functions, and ease of operation.
- V/F control mode enables high-precision current limit control, ensuring no overcurrent alarm during fast acceleration/deceleration or stall.
- Vector control mode enables high-precision torque limiting control, allowing the drive to output either strong or soft torque according to the user's process control requirements, thus protecting the mechanical equipment.
- V/F separation control mode allows the output frequency and output voltage to be set separately, making it suitable for applications such as inverter power supplies and torque motor control.
|
Control Mode |
Start Torque |
Speed Range |
Speed Precision |
Torque Response |
|
V/F control |
0.5Hz 180% |
1:100 |
±0.5% |
|
|
Vector control without PG |
0.5Hz 180% |
1:100 |
±0.2% |
<10mS |
- This low voltage drive provides accurate and reliable speed search for smooth, shock-free starting of rotating motors.
- The process PID control features a rich set of settings and feedback methods, allowing the free switching between two sets of proportional, integral, and differential parameters. It is especially suitable for energy-saving applications in fans and pump loads.

- DC power input is supported, enabling users to conveniently form a common DC bus application.
- Overvoltage stall protection: During the rapid deceleration of large inertia loads, regenerative energy may lead to overvoltage faults. The instantaneous adjustment of the output frequency can reduce the probability of overvoltage tripping, ensuring the continuous and reliable operation of the system.

- Undervoltage adjustment: In case of instantaneous undervoltage or power failure, the DC bus voltage remains constant through the automatic reduction of the output frequency, ensuring the continuous operation of the drive within a short time. This function applies to fans and pumps.
- Overcurrent stall protection function: During the fast acceleration of a heavy load, instantaneous large slip may result in an overcurrent fault. The instantaneous adjustment of the output frequency can reduce the probability of overcurrent tripping, ensuring the continuous and reliable operation of the system.

- Low-frequency oscillation suppression function: During the no-load or light-load start of a large power motor, acute oscillations may occur, leading to fault tripping. Enabling this function effectively suppresses oscillations and ensures the reliable operation of the system.
- Automatic torque boost: In V/F control mode, the output torque is automatically adjusted according to the load condition, allowing for smooth starts under light load, no load, or even overloaded conditions.

Product Specification
|
Items |
Indicator and specifications |
|
|
Input-output characteristics |
Input voltage range |
Three-phase 380VAC (±15%), Single-phase 220VAC (±15%). |
|
Input frequency range |
50~60Hz±5% |
|
|
Output voltage range |
0~Rated input voltage |
|
|
Output frequency range |
0~500Hz |
|
|
Technical characteristics |
Control mode |
V/F control; No PG vector control, torque control. |
|
Speed control range |
Open-loop vector control 1: 100 |
|
|
Speed control accuracy |
±0.5% |
|
|
Starting frequency |
0.00~10.00Hz |
|
|
Overload capacity |
150% rated current 60s; 180% rated current 10s; 200% rated current 1s. |
|
|
Acceleration and Deceleration time |
0.1~3000.0s |
|
|
Dynamic braking capacity |
Brake unit operating voltage: 320~750V |
|
|
DC braking capacity |
DC braking frequency: 0~300Hz; DC braking waiting time: 0~50s; DC braking current: 0.0~150.0%; DC braking time: 0.0~50.0s. |
|
|
Frequency setting method |
Analog setting, High-speed pulse setting, Multi-segment command setting, PID control setting, 485 communication setting. |
|
|
Automatic voltage adjustment |
It can keep a constant voltage output when the power grid voltage changes |
|
|
Speed search starting |
Enables smooth and shock-free starting of rotating motors |
|
|
Control terminals |
Digital input terminal |
8 inputs as standard, one of which can be used as a high-speed pulse input (HDI). |
|
Analog input terminals |
2 inputs as standards , AI1: 0~10V or 0/4~20mA input selectable; AI2: 0~10V or 0/4~20mA input selectable |
|
|
Digital output terminals |
2 multifunction collector outputs as standard, one of which can be used as a high- speed pulse output (HDO). |
|
|
Analog output terminals |
2 outputs as standard AO1, AO2 (0~10V or 0/4~20mA selectable). |
|
|
Relay output |
2 relay outputs as standard |
|
|
Standard communication interface |
RS485 communication |
Provide RS485 communication interface to communicate with external RS485 and support Modbus protocol (RTU mode). |
|
Fault protection |
Acceleration overcurrent, deceleration overcurrent, constant speed overcurrent, acceleration overvoltage, deceleration overvoltage, constant speed overvoltage, Bus undervoltage fault, motor overload, VFD overload, input phase loss error, output phase loss error, rectifier module overheating fault, inverter module overheating fault, external fault, communication fault, current detection fault, motor parameter recognition fault, EEPROM operation fault, PID feedback disconnection, brake unit fault, manufacturer-set time reached. |
|
|
Keyboard display |
LED |
Bright LED digital tube displays information about VFD |
|
Others |
Operation place |
Indoor, at an altitude of less than 1,000 meters above sea level, free from direct sunlight, dust, corrosive gases, etc. |
|
Ambient temperature |
-10~+40℃, the device should be used with reduced capacity in 40~50℃, The rated output current should be reduced by 1% for every 1℃ of increase. |
|
|
Humidity |
5~95% (no condensation) |
|
|
Altitude |
0~2000 meters, the device should be used with reduced capacity when above 1000 meters. The rated output current should be reduced by 1% for every 100 meters of elevation. |
|
|
Vibration |
Less than 0.5g |
|
|
Storage temperature |
-40~+70℃ |
|
|
Protection level |
IP20 |
|
|
Model |
Power (kW) |
Input voltage(V) |
Input current (A) |
Output current (A) |
Power of applicable motor (kW) |
Note |
|
RNB1000G-2S |
0.75 |
Single-phase 220V |
8.2 |
4.5 |
0.75 |
|
|
RNB1001G-2S |
1.5 |
14 |
7 |
1.5 |
||
|
RNB1002G-2S |
2.2 |
23 |
9.6 |
2.2 |
||
|
RNB1000G |
0.75 |
3.4 |
2.5 |
0.75 |
||
|
RNB1001G |
1.5 |
5 |
3.8 |
1.5 |
||
|
RNB1002G |
2.2 |
5.8 |
5.3 |
2.2 |
||
|
RNB1004G/005P |
4.0 |
12 |
9.5 |
4.0 |
||
|
5.5 |
18.5 |
14 |
5.5 |
|||
|
RNB1005G/007P |
5.5 |
18.5 |
14 |
5.5 |
||
|
7.5 |
22.5 |
18.5 |
7.5 |
|||
|
RNB1007G/011P |
7.5 |
22.5 |
18.5 |
7.5 |
||
|
11 |
30 |
25 |
11 |
|||
|
Built-in |
||||||
|
11 |
30 |
25 |
11 |
brake |
||
|
RNB1011G/015P |
unit as standard |
|||||
|
15 |
39 |
32 |
15 |
|||
|
RNB1015G/018P |
15 |
39 |
32 |
15 |
||
|
18.5 |
45 |
38 |
18.5 |
|||
|
RNB1018G/022P |
18.5 |
45 |
38 |
18.5 |
||
|
22 |
54 |
45 |
22 |
|||
|
RNB1022G/030P |
22 |
Three-phase |
54 |
45 |
22 |
|
|
30 |
68 |
60 |
30 |
|||
|
380V |
||||||
|
30 |
68 |
60 |
30 |
|||
|
RNB1030G/037P |
||||||
|
37 |
84 |
75 |
37 |
|||
|
RNB1037G/045P |
37 |
84 |
75 |
37 |
||
|
45 |
98 |
92 |
45 |
|||
|
RNB1045G/055P |
45 |
98 |
92 |
45 |
||
|
55 |
123 |
115 |
55 |
|||
|
RNB1055G/075P |
55 |
123 |
115 |
55 |
||
|
75 |
157 |
150 |
75 |
|||
|
RNB1075G/090P |
75 |
157 |
150 |
75 |
Optional built-in |
|
|
90 |
188 |
180 |
90 |
|||
|
brake unit |
||||||
|
90 |
188 |
180 |
90 |
|||
|
RNB1090G/110P |
||||||
|
110 |
221 |
215 |
110 |
|||
|
RNB1110G/132P |
110 |
221 |
215 |
110 |
||
|
132 |
267 |
260 |
132 |
|||
|
RNB1132G/160P |
132 |
267 |
260 |
132 |
||
|
160 |
309 |
305 |
160 |
|
Model |
Power (kW) |
Input voltage(V) |
Input current (A) |
Output current (A) |
Power of applicable motor (kW) |
Note |
|
RNB1160G/185P |
160 |
Three-phase 380V |
309.0 |
305 |
160 |
|
|
185 |
344.0 |
340 |
185 |
|||
|
RNB1185G/200P |
185 |
344.0 |
340 |
185 |
||
|
200 |
384.0 |
380 |
200 |
|||
|
RNB1200G/220P |
200 |
384.0 |
380 |
200 |
||
|
220 |
429.0 |
425 |
220 |
|||
|
RNB1220G/250P |
220 |
429.0 |
425 |
220 |
||
|
250 |
484.0 |
480 |
250 |
|||
|
RNB1250G/280P |
250 |
484.0 |
480 |
250 |
||
|
280 |
539.0 |
530 |
280 |
|||
|
RNB1280G/315P |
280 |
539.0 |
530 |
280 |
||
|
315 |
612.0 |
600 |
315 |
|||
|
RNB1315G/350P |
315 |
612.0 |
600 |
315 |
||
|
350 |
665.0 |
650 |
350 |
|||
|
RNB1350G |
350 |
665.0 |
650 |
350 |
||
|
RNB1400G |
400 |
715 |
720 |
400 |
||
|
RNB1450G |
450 |
805 |
795 |
450 |
||
|
RNB1500G |
500 |
890 |
860 |
500 |
NOTE 1: Brake units are standard for models RNB1037G/045P (inclusive). Models RNB1045G/055P (inclusive) to RNB1132G/160P (inclusive) can be equipped with a built-in brake unit as an option.