Low Voltage Drive
video
Low Voltage Drive

Low Voltage Drive

The RNB1000 series low voltage drive made by RENLE is suitable for three-phase squirrel-cage asynchronous motors. With its compact structure and high reliability, the RNB1000 series VFD is widely used in manufacturing, transportation, and other industries.
• Various fans and pumps equipment;
• Ceramic machinery;
• Machine tools;
• Woodworking machinery;
• Packaging and printing machinery;
• Material transportation equipment and other universal
• equipment (conveyor and hoisting).

Model Description

 

The letters and numbers on the nameplate indicate the product series, power, applicable load type and so on.

R N B 1 X X X G / X X X P product-24-3 X

product-537-321

Specialized Machine Code

Power Code 1000 Series

Variable Frequency Drive

Shanghai RENLE Science & Technology Co., Ltd.

Character

Description

RN

Shanghai RENLE Science & Technology Co., Ltd.

B

Low-voltage Variable Frequency Drive

1

1000 Series

XXXG/XXXP

Power Code:

G: Constant torque load (Heavy load) P: Variable torque load (light load) G/P: G/P-model in one

XXX: Power code: such as 001: 1.5kW; 037: 37kW; 110: 110kW

-X

Specialized machine code: No code indicates universal model

-2S: Single-phase 220VAC input, Three-phase 220VAC output;

-2SS: Single-phase 220VAC input, Single-phase 220VAC output.

Achieve rapid deployment and intuitive operation for enhanced productivity.

The cabinet-ready, space-saving RNB1000 low voltage drive provides essential functionalities out of the box. Its streamlined setup menu and guided tools facilitate swift installation, configuration, operation, and servicing.

Designed to boost operational effectiveness and ease across diverse applications

The RNB1000 LV VFD integrates features that simplify drive selection and minimize reliance on additional components. Optimized for both variable torque and basic constant torque applications, it prioritizes a straightforward design, dependable performance, and energy savings. The drive's intuitive interface accelerates startup and commissioning.

Technical data

 

Enhanced operational efficiency and seamless integration across diverse industrial environments, leveraging integrated functionalities to streamline installation, tuning, and runtime.

  • Up to 500 kW
  • Wide power range from 0.75 kW
  • Up to 480 V
  • Wide voltage range from 220 V

 

Key benefits

 

  • V/F Control Mode: Effectively protects the drive.
  • Vector Control Mode: High-precision torque limiting control.
  • V/F Separation Control Mode: The output frequency and output voltage can be set separately, making it suitable for various applications, such as variable frequency power supplies.
  • Newly designed panel keyboard with superior operability, supporting dual-row display.

 

Product Feature

 

The RNB1000 series Low Voltage Drive VFD improves production efficiency for the majority of users through its compact structure, powerful functions, and ease of operation.

  • V/F control mode enables high-precision current limit control, ensuring no overcurrent alarm during fast acceleration/deceleration or stall.
  • Vector control mode enables high-precision torque limiting control, allowing the drive to output either strong or soft torque according to the user's process control requirements, thus protecting the mechanical equipment.
  • V/F separation control mode allows the output frequency and output voltage to be set separately, making it suitable for applications such as inverter power supplies and torque motor control.

 

Control Mode

Start Torque

Speed Range

Speed Precision

Torque Response

V/F control

0.5Hz 180%

1:100

±0.5%

 

Vector control without PG

0.5Hz 180%

1:100

±0.2%

<10mS

 
  • This low voltage drive provides accurate and reliable speed search for smooth, shock-free starting of rotating motors.
  • The process PID control features a rich set of settings and feedback methods, allowing the free switching between two sets of proportional, integral, and differential parameters. It is especially suitable for energy-saving applications in fans and pump loads.
speed search start

 

 
  • DC power input is supported, enabling users to conveniently form a common DC bus application.
  • Overvoltage stall protection: During the rapid deceleration of large inertia loads, regenerative energy may lead to overvoltage faults. The instantaneous adjustment of the output frequency can reduce the probability of overvoltage tripping, ensuring the continuous and reliable operation of the system.
Overvoltage suppression
 
  • Undervoltage adjustment: In case of instantaneous undervoltage or power failure, the DC bus voltage remains constant through the automatic reduction of the output frequency, ensuring the continuous operation of the drive within a short time. This function applies to fans and pumps.
  • Overcurrent stall protection function: During the fast acceleration of a heavy load, instantaneous large slip may result in an overcurrent fault. The instantaneous adjustment of the output frequency can reduce the probability of overcurrent tripping, ensuring the continuous and reliable operation of the system.
Undervoltage adjustment
 
  • Low-frequency oscillation suppression function: During the no-load or light-load start of a large power motor, acute oscillations may occur, leading to fault tripping. Enabling this function effectively suppresses oscillations and ensures the reliable operation of the system.
  • Automatic torque boost: In V/F control mode, the output torque is automatically adjusted according to the load condition, allowing for smooth starts under light load, no load, or even overloaded conditions.
Overcurrent stall protect function

Product Specification

 

 

Items

Indicator and specifications

 

Input-output

characteristics

Input voltage range

Three-phase 380VAC (±15%), Single-phase 220VAC (±15%).

Input frequency range

50~60Hz±5%

Output voltage range

0~Rated input voltage

Output frequency range

0~500Hz

Technical characteristics

Control mode

V/F control; No PG vector control, torque control.

Speed control range

Open-loop vector control 1: 100

Speed control accuracy

±0.5%

Starting frequency

0.00~10.00Hz

Overload capacity

150% rated current 60s; 180% rated current 10s; 200% rated current 1s.

Acceleration and

Deceleration time

0.1~3000.0s

Dynamic braking capacity

Brake unit operating voltage: 320~750V

DC braking capacity

DC braking frequency: 0~300Hz; DC braking waiting time: 0~50s; DC braking current: 0.0~150.0%; DC braking time: 0.0~50.0s.

Frequency setting

method

Analog setting, High-speed pulse setting, Multi-segment command setting,

PID control setting, 485 communication setting.

Automatic voltage

adjustment

It can keep a constant voltage output when the power grid voltage changes

Speed search starting

Enables smooth and shock-free starting of rotating motors

 

 

Control terminals

Digital input terminal

8 inputs as standard, one of which can be used as a high-speed pulse input (HDI).

Analog input terminals

2 inputs as standards , AI1: 0~10V or 0/4~20mA input selectable;

AI2: 0~10V or 0/4~20mA input selectable

Digital output terminals

2 multifunction collector outputs as standard, one of which can be used as a high-

speed pulse output (HDO).

Analog output terminals

2 outputs as standard AO1, AO2 (0~10V or 0/4~20mA selectable).

Relay output

2 relay outputs as standard

Standard communication

interface

RS485 communication

Provide RS485 communication interface to communicate with external RS485 and support Modbus protocol (RTU mode).

 

Fault protection

Acceleration overcurrent, deceleration overcurrent, constant speed overcurrent, acceleration overvoltage, deceleration overvoltage, constant speed overvoltage, Bus undervoltage fault, motor overload, VFD overload, input phase loss error, output phase loss error, rectifier module overheating fault, inverter module overheating fault, external fault, communication fault, current detection fault, motor parameter recognition fault, EEPROM operation

fault, PID feedback disconnection, brake unit fault, manufacturer-set time reached.

Keyboard

display

LED

Bright LED digital tube displays information about VFD

Others

Operation place

Indoor, at an altitude of less than 1,000 meters above sea level, free from direct

sunlight, dust, corrosive gases, etc.

Ambient temperature

-10~+40℃, the device should be used with reduced capacity in 40~50℃,

The rated output current should be reduced by 1% for every 1℃ of increase.

Humidity

5~95% (no condensation)

Altitude

0~2000 meters, the device should be used with reduced capacity when above 1000 meters.

The rated output current should be reduced by 1% for every 100 meters of elevation.

Vibration

Less than 0.5g

Storage temperature

-40~+70℃

Protection level

IP20

 

Model

Power

(kW)

Input

voltage(V)

Input

current (A)

Output

current (A)

Power of applicable

motor (kW)

Note

RNB1000G-2S

0.75

 

Single-phase

220V

8.2

4.5

0.75

 

RNB1001G-2S

1.5

14

7

1.5

 

RNB1002G-2S

2.2

23

9.6

2.2

 

RNB1000G

0.75

 

3.4

2.5

0.75

 

RNB1001G

1.5

 

5

3.8

1.5

 

RNB1002G

2.2

 

5.8

5.3

2.2

 

RNB1004G/005P

4.0

 

12

9.5

4.0

 

5.5

18.5

14

5.5

RNB1005G/007P

5.5

 

18.5

14

5.5

 

7.5

22.5

18.5

7.5

RNB1007G/011P

7.5

 

22.5

18.5

7.5

 

11

30

25

11

   

Built-in

 

11

 

30

25

11

brake

RNB1011G/015P

 

unit as standard

15

39

32

15

RNB1015G/018P

15

 

39

32

15

 

18.5

45

38

18.5

RNB1018G/022P

18.5

 

45

38

18.5

 

22

54

45

22

RNB1022G/030P

22

 

Three-phase

54

45

22

 

30

68

60

30

 

380V

 
 

30

68

60

30

RNB1030G/037P

   

37

84

75

37

RNB1037G/045P

37

 

84

75

37

 

45

98

92

45

RNB1045G/055P

45

 

98

92

45

 

55

123

115

55

RNB1055G/075P

55

 

123

115

55

 

75

157

150

75

RNB1075G/090P

75

 

157

150

75

Optional

built-in

90

188

180

90

   

brake unit

 

90

188

180

90

RNB1090G/110P

   

110

221

215

110

RNB1110G/132P

110

 

221

215

110

 

132

267

260

132

RNB1132G/160P

132

 

267

260

132

 

160

309

305

160

 

Model

Power

(kW)

Input

voltage(V)

Input

current (A)

Output

current (A)

Power of applicable

motor (kW)

Note

RNB1160G/185P

160

 

 

 

 

 

 

 

 

 

Three-phase 380V

309.0

305

160

 

185

344.0

340

185

RNB1185G/200P

185

344.0

340

185

200

384.0

380

200

RNB1200G/220P

200

384.0

380

200

220

429.0

425

220

RNB1220G/250P

220

429.0

425

220

250

484.0

480

250

RNB1250G/280P

250

484.0

480

250

280

539.0

530

280

RNB1280G/315P

280

539.0

530

280

315

612.0

600

315

RNB1315G/350P

315

612.0

600

315

350

665.0

650

350

RNB1350G

350

665.0

650

350

RNB1400G

400

715

720

400

RNB1450G

450

805

795

450

RNB1500G

500

890

860

500

 

NOTE 1: Brake units are standard for models RNB1037G/045P (inclusive). Models RNB1045G/055P (inclusive) to RNB1132G/160P (inclusive) can be equipped with a built-in brake unit as an option.

NOTE 2: The above models are standard general-purpose models, without industry-specific variants. Other specifications for non-standard models can be customized.

Hot Tags: low voltage drive, China low voltage drive manufacturers, suppliers, factory, liquid cooled vfd, 1ph vfd, single phase to three phase variable frequency drive, 3 phase variable speed drive, drive variable frequency, 50hz to 60hz inverter

Send Inquiry