Product Introduction
The 6.6 kV soft starter is a solid-state, medium-voltage device designed for three-phase induction motors. It controls motor acceleration, deceleration, and protection by adjusting the output voltage through thyristor conduction angle regulation. This enables smooth starting and stopping operations, greatly reducing inrush current to the power supply and decreasing mechanical stress on driven equipment and couplings. As a result, electrical grid disturbances are minimized, and mechanical components are protected from shock loads.
Medium-voltage systems are inherently complex-your starter shouldn't complicate them further. RENLE's RNMV-EI medium-voltage soft starter simplifies operation with user-friendly features such as plain-language diagnostics, eliminating the need for code deciphering. Built-in monitoring, status indicators, and comprehensive I/O options save space and reduce auxiliary costs, while also speeding up commissioning. Real-time motor performance curves and current readings offer clear visibility into operating conditions. With intuitive feedback in everyday language, the RNMV-EI enables straightforward starting control-no manual decoding required.
Rated voltage: 3kV/3.3kV/4.16kV/
6kV/6.6kV/10kV/
11kV/13.8kV
Rated power:
250kW-15000kW;
Starting current: Adjustable range 1.5-5 times;
Adopt serial thyristor valve group and dual power supply trigger technology;
Products advantages

5G Industrial Ethernet & Cloud Connectivity
This system leverages 5G industrial Ethernet combined with a cloud platform to deliver comprehensive remote technical support for field equipment. It enables a complete operational cycle, from data acquisition and waveform display to remote diagnostics and software updates.
Multi-Protocol Communication Support
The starter offers extensive connectivity options, supporting protocols including Modbus RTU, Modbus TCP, and PROFIBUS DP. Multiple reserved interfaces facilitate easy parameter configuration and real-time data monitoring. Additionally, with dedicated software tools, users can perform remote waveform analysis, data downloads via FTP/TFTP, and seamless software upgrades.

Operation Panel Description
This 6.6kV Soft Starter series of Intelligent high-voltage solid-state soft starting cabinets use PLC andHMI (Human-Machine Interface, refer to touchscreen) as peripheral application extensions,PLC as peripheral terminal function extensions, and HMI as Intelligent high-voltage solid and state soft starting cabinet status monitoring and parameter modification.

Function Overview
The 6.6kV Soft Starter main components include:
one HMI
one DC24V Power Supply
one vacuumcontactor for bypass
three CT
three voltage sensors
main controller
power modul
|
Function Items |
Function Description |
|
Start Up |
Constant Current |
|
Current ramp |
|
|
Stop |
Coast to stop |
|
Soft stop |
|
|
Protect |
Zero sequence overcurrent protection |
|
Component overheat protection |
|
|
Grounding protection |
|
|
Undervoltage protection |
|
|
Transient ovecurrent |
|
|
Time limit current (start-up) |
|
|
Output open-phase |
|
|
Trigger board power protection |
|
|
RC Current Protection |
|
|
SCR Overvoltage trigger protection |
|
|
I/O |
Programmable input (10) |
|
AQ |
Programmable analog output (1) |
|
Communication |
One Modbus_RTU/PROFIBUS_DP (RS485) |
|
One Modbus_TCP/IP (RJ45) |
|
|
CAN Bus |
|
|
One Modbus_RTU (RS485) used to connect the HMI of the cabinet |
Medium voltage Starter Selection Table
|
Valve group current (A) |
Voltage (kV) |
Max. power of universal motor (kW) |
Specifications |
Cabinet dimensions (H×W×D,mm) |
Weight (t) |
|
150 |
3 |
630 |
RNMV-030150 |
2300*800*1500 |
0.7 |
|
150 |
3.3 |
650 |
RNMV-033150 |
2300*800*1500 |
0.7 |
|
150 |
6 |
1250 |
RNMV-060150 |
2300*800*1500 |
0.7 |
|
150 |
6.6 |
1350 |
RNMV-066150 |
2300*800*1500 |
0.7 |
|
150 |
10 |
2000 |
RNMV-100150 |
2300*800*1500 |
0.75 |
|
150 |
11 |
2240 |
RNMV-110150 |
2300*800*1500 |
0.75 |
|
330 |
3 |
1350 |
RNMV-030330 |
2300*1000*1500 |
0.78 |
|
330 |
3.3 |
1500 |
RNMV-033330 |
2300*1000*1500 |
0.78 |
|
330 |
6 |
2700 |
RNMV-060330 |
2300*1000*1500 |
0.8 |
|
330 |
6.6 |
3000 |
RNMV-066330 |
2300*1000*1500 |
0.8 |
|
330 |
10 |
4500 |
RNMV-100330 |
2300*1000*1500 |
0.8 |
|
330 |
11 |
5000 |
RNMV-110330 |
2300*1000*1500 |
0.8 |
|
500 |
3 |
2000 |
RNMV-030500 |
2300*1100*1500 |
0.85 |
|
500 |
3.3 |
2240 |
RNMV-033500 |
2300*1100*1500 |
0.85 |
|
500 |
6 |
4000 |
RNMV-060500 |
2300*1100*1500 |
0.85 |
|
500 |
6.6 |
4500 |
RNMV-066500 |
2300*1100*1500 |
0.85 |
|
500 |
10 |
6800 |
RNMV-100500 |
2300*1100*1500 |
1 |
|
500 |
11 |
7600 |
RNMV-110500 |
2300*1100*1500 |
1 |
|
700 |
3 |
2800 |
RNMV-030700 |
2300*1200*1500 |
1 |
|
700 |
3.3 |
3150 |
RNMV-033700 |
2300*1200*1500 |
1 |
|
700 |
6 |
5800 |
RNMV-060700 |
2300*1200*1500 |
1.2 |
|
700 |
6.6 |
6300 |
RNMV-066700 |
2300*1200*1500 |
1.2 |
|
700 |
10 |
9600 |
RNMV-100700 |
2300*1200*1500 |
1.25 |
|
700 |
11 |
10000 |
RNMV-110700 |
2300*1200*1500 |
1.25 |
|
1000 |
3 |
4000 |
RNMV-0301000 |
2300*1400*1500 |
1.5 |
|
1000 |
3.3 |
4500 |
RNMV-0331000 |
2300*1400*1500 |
1.5 |
|
1000 |
6 |
8200 |
RNMV-0601000 |
2300*1400*1500 |
1.8 |
|
1000 |
6.6 |
9100 |
RNMV-0661000 |
2300*1400*1500 |
1.8 |
|
1000 |
10 |
13500 |
RNMV-1001000 |
2300*1400*1500 |
1.8 |
|
1000 |
11 |
15000 |
RNMV-1101000 |
2300*1400*1500 |
1.8 |
Technical Parameters
| Data Name | Working Range |
| Frequency | 50Hz/60Hz±2Hz(selected according to user's grid) |
| Overload capacity | 400% control nominal value 60s |
| 500% control nominal value 30s | |
| Applicable motor | Three-phase squirrel-cage asynchronous and synchronous motor |
| Application environment | |
| Temperature | Cabinet temperature 0°C~40°C, (Heater is optional for -20°C~0°C) |
| Humidity | 5%~95% relative humidity |
| Altitude | Below 2000m. Derating is necessary for altitude above 2000m. |
| Place | Indoors, no explosive or corrosive gas, with low dust |
| Cooling | Natural cooling |
| Structural features | |
| Protection level | IP4X |
| Operation power supply | 2kVA AC220V supplied by the user (can be specified). |
| Main circuit | The number of thyristors is determined by the model. |
| Communication protocol | Integrated Modbus RTU, Modbus TCP, CAN and PROFIBUS DP communication protocols, equipped with interface. |
| Communication interface | RJ45 |
| Operation interface | 7-inch touch screen (HMI) which monitors system status in real-time. Used for setting and modifying parameters. |
| Event record | It can continuously record events and historical curves with time and date stamps within 10 days. |
| Performance monitoring | Current, voltage, power factor, module temperature, RC average and peak voltage, RC current, etc. |
| Input and output options | 10 channels of 24VDC programmable inputs, 2 channels of 16A and 4 channels of 5A programmable outputs, 1 analog programmable output (4~20mA). |
| User management | Multi-level user password protection (can be specified). |
| Interface language | Chinese, English, Russian (can be specified) |
| Thyristor | Thyristor valve group in series |
| Drive and data | Dual power supply triggering, optical fiber communication multiplexing technology; |
| Adopting synchronous phase-locked loop, three-phase conduction compensation algorithm; | |
| Equipped with OBD and software double overvoltage function; | |
| After startup is completed, the valve group limit data are counted for evaluating the system status. | |
| Monitoring | HMI window, used for real-time monitoring of system status, collection of valve group data and setting and modification of control parameters. |
| Protection | Undervoltage, overvoltage, phase loss, overheating, abnormal voltage sharing, abnormal RC current, thyristor failure, optical fiber communication interruption, abnormal triggering power supply etc. |
| Cloud service | Remote software update, commissioning, data waveform monitoring and fault analysis is realized through InterNet; |
| After connecting to the cloud server through industrial Ethernet + 5G, the soft starter provides data for big data analysis and related AI algorithms; | |
| makes full use of the computing power of the cloud platform to realize online analysis and diagnosis of motor operating status, and realizes fault pre-warning and optimized control. | |
| Cabinet color | Selected by the user. |
| Start data | |
| Starting current | Adjustable within 4 times of the rated current of the motor. |
| Starting time | Adjustable within 10~60 seconds. |
| Number of starts | 6 times per hour at an ambient temperature of 25°C. |
| Starting interval | No less than 5 minutes between two starts. |
| Protection parameters | |
| Transient overcurrent | Protection range 200%~800% |
| Inverse time overcurrent | The protection time is 1 minute for 1.5 times, used for protecting the motor during bypass operation. |
| Incoming line undervoltage | Range: 0%~100% |
| Grounding | Ground protection is identified by zero-sequence current. |
| Output phase loss | Set the threshold 1.0%~50% according to the parameters by comparison of the three-phase output current. |
| Thyristor breakdown | Set action threshold through parameters by monitoring voltage of each level of thyristors. |
| RC current | Monitor RC current of each level of thyristors and identity RC working status. Current deviation can be set. |
| Trigger failure | During startup, the number of triggering failure exceeds the set parameter value within 2 seconds of detection window, so protection acts. |
| Start timeout | The start time exceeds the set value. |
| Triggering power | If the power of the triggering board is lower or higher than the hardware protection value, protection of triggering board power acts. |
| Temperature | SCR temperature exceeds the set parameters. |
| Thyristor overvoltage | During the starting process, each level of SCR is equipped with OBD protection. During one starting process, the number of overvoltage automatic triggering reaches the set parameter, the protection is performed. |
Hot Tags: 6.6kv soft starter, China 6.6kv soft starter manufacturers, suppliers, factory, Medium Voltage Solid State Starter, 6.6 kv soft starter, 3 phase soft starter, 4160v motor starter, vfd starter for motor, aircon soft starter